With last Monday’s North American total solar eclipse throwing a lot of things off (ask me about my nine-hour drive from Vermont to Boston!), this is a good week for catching up on the blog backlog. So, nearly five years after I published it, here’s a quick advertisement for a radio interferometric peeling tool (code, publication) that I’ve developed. This post will describe the associated workflow in a bit more detail than could fit in the length-constrained Research Note (Williams et al., 2019) that presented the tool.

Fair warning: I’m going to get right into the weeds since this is a specialist topic.

When you’re doing interferometric imaging with a telescope like the VLA, very bright sources are often a problem. In interferometery, calibration errors generally scatter flux from true sources across your image, potentially corrupting the measurements of whatever features you’re interested in. People interested in interferometric techniques therefore often spend a lot of time worrying about the dynamic range that they’re achieving, measured as the ratio of the brightest part of the image to some kind of noise metric (e.g., Braun 2013). Standard calibration techniques should easily achieve a dynamic range much better than 100:1 (e.g., 1% scattering), and if that’s good enough, fine. But if you have a bright source in your field, you might need to use more sophisticated calibration to reach for 10000:1 or even better, because 1% of a big number might be enough to cause problems for your science.

Standard interferometric calibration techniques are “direction-independent”: they compute various parameters that are, in a certain sense, based on the total flux arriving at the telescope from the field that it's looking at, without paying attention to where exactly the flux is coming from. To get more sophisticated, often one adopts “direction-dependent” calibrations: your antennas aren’t perfect, and so the telescope’s response to flux from one part of the sky isn’t the same as its response to the same amount of flux from another part of the sky. Accounting for this reality requires a more complex instrument model and extra computation, but can yield significantly better results.

In the simplest situation, after solving for a direction-independent (DI) calibration, you might discover that a nuisance source dominates your image. If it’s bright enough and sufficiently easy to model, you should be able to self-calibrate to obtain a direction-dependent (DD) calibration optimized for that one particular source. If that source is off in the sidelobes of your antennas, those calibration parameters might be very different than the DI calibration parameters, which are generally derived by pointing your telescope right at a calibrator.

In this scenario, the emission from your science target(s) is still best calibrated using the DI parameters. So, you basically want to analyze the data using two different calibrations at the same time — but how? Some radio imaging tools can do this, but if we’re not using one of them, we’re not necessarily out of luck. In the “peeling” technique (e.g. Noordam 2004), we simply subtract the source away in the visibility domain. To the extent that our system is linear, and our calibrations are invertible, and that we can model our source (hopefully all pretty good assumptions), this will get rid of the source and allow us to proceed with standard DI analysis as if it was never even there.

For the Allers+ 2020 windspeeds paper, this was what I wanted to do. But as far as I was able to tell (and to my knowledge, this is still true), the standard CASA analysis package didn’t provide all of the tools necessary to peel. Most of the elements were there, but you need some mechanism to, essentially, invert a set of calibration gains, and I couldn't see any way to do that with the out-of-the-box tasks. Meanwhile, I couldn't find any third-party peeling tools that looked like they could plug into an otherwise fairly vanilla VLA cm-wavelength analysis.

But the underlying computation isn’t that complex, and it can be implemented if you’re willing and able to write some code to edit your Measurement Sets directly. You could do it in Python, but I had been experimenting with building an interface between the CASA data formats and the Rust language, a project called rubbl. For the large, complex data sets that you get in radio interferometry, Rust is worth it — I’ve implemented data-processing steps that become 10 times faster after porting from Python to Rust, and that’s not even factoring in the way that you can implement parallel algorithms in Rust in a way that Python just can’t handle. (If you’re using python-casacore naively, at least; systems like dask-ms might improve things.)

So I ended up implementing the missing step inside a toolkit called rubbl-rxpackage, in a command-line tool called rubbl rxpackage peel. (There are a couple of other mini-tasks inside rubbl-rxpackage, but not many.)

The rxpackage peel tool implements only the very specific calibration-inversion step that I found to be missing from mainline CASA. To actually implement peeling in a pipeline, you need to include the tool within a broader set of steps in your workflow. The associated Research Note describes this workflow, but length limitations forced it to be quite terse. Below I reproduce the description in the note in an expanded format.

The Peeling Workflow🔗

Assume that we have two Measurement Sets, main.ms and work.ms. The fundamental operation implemented by the peel command is to perform the following update:

main.ms[MODEL_DATA] +=
  work.ms[MODEL_DATA] * (work.ms[DATA] / work.ms[CORRECTED_DATA])

Basic calibrations are multiplicative: CORRECTED_DATA = (calibration) * DATA. So the ratio DATA / CORRECTED_DATA is the inverse calibration term that we need, and the effect of the command is to update a MS model with another model perturbed by an inverted calibration. By computing the inversion this way (as opposed to, say, futzing with gain calibration tables directly, which was the first approach I considered), we get the nice property that we can invert any multiplicative calibration, without worrying about how exactly it was derived.

With this building block, we can peel. We’ll assume that we have n > 0 bright nuisance sources to peel, numbered sequentially with an index i by decreasing total flux. The steps are as follows.

  1. Image main.ms[DATA], obtaining a CLEAN component image main.model. (Or multiple model images, if you’re using MFS with Taylor terms, etc.). So, we’re assuming that you’ve used a task like split to apply your DI calibration to your dataset. In the abstract this isn’t necessary, but CASA’s triple-data-column paradigm kind of forces you into this.
  2. For each bright source to peel ...
    1. Create a CLEAN component image template.$i.model, where $i is the index number of the bright source in question. In this component image, zero out the sources with index numbers ji. That is, edit the actual component model image data to replace the pixel values around the bright source and the already-peeled ones with zeros. This requires some custom Python code, but it's straightforward and not I/O-intensive.
    2. Use the task ft to fill main.ms[MODEL_DATA] with the Fourier transform of template.$i.model. This set of model visibilities therefore captures the non-nuisance sources, and any bright sources that we haven’t yet started dealing with.
    3. For each previously peeled source with index j < i, use the peeling tool with its work MS (see blow). This will update main.ms[MODEL_DATA] to add in the best-available DD-calibrated models for these sources. Once this is done, the model will capture everything in the image except the ith nuisance source, because we zeroed it out when creating template.$i.model. We also zeroed out the j < i sources, but now we’ve added them back in.
    4. Clear main.ms[CORRECTED_DATA] and use the task uvsub, which will set CORRECTED_DATA = MODEL_DATA - DATA. This will leave the CORRECTED_DATA column containing only source i — the things that are not in the model are the ones that remain after we subtract the model. Of course, this only holds to the extent that our calibrations and models are accurate, but if we’re focusing on mitigating bright nuisance sources, the imperfections shouldn’t be significant, by definition.
    5. Use the task split to create a new dataset work.$i.ms. Its DATA column will be equal to this CORRECTED_DATA column, so it will contain only the signal from source i. This signal has had the DI calibration applied, but still could benefit from additional DD calibration.
    6. Fill work.$i.ms[MODEL_DATA] with a model of source i, using whatever standard CASA tools are appropriate. E.g., you might use the “component list” functionality and the ft task.
    7. Use CASA’s standard calibration routines to determine a source-specific self-calibration for source i. You can use whatever calibrations are appropriate, so long as their net result is multiplicative on a per-visibility basis. You don’t have to worry about absolute flux calibration since we only care about removing the source in the “uncalibrated frame”. We now have the DD calibration for our source, since we subtracted all of the flux for everything that is not our source.
    8. Use task applycal to, well, apply the calibrations, filling in work.$i.ms[CORRECTED_DATA]. The only reason we need to do this is so that the peeling tool can then figure out the inverse calibration by computing the ratio DATA / CORRECTED_DATA. If there were a way to directly invert the calibration parameters obtained in the previous step, we could skip this step, but I would only feel confident doing so with unrealistically trivial calibrations.
  3. After doing the above, we have i copies of our dataset, stored in the work.$i.ms, each of which encodes the DD calibration solution associated with its corresponding bright nuisance source. Clear MODEL_DATA and CORRECTED_DATA in main.ms.
  4. Now, for each bright source, use the peeling tool. This will build up the MODEL_DATA column of main.ms to contain only the DD-calibrated models of the bright nuisance sources. Note that, if the calibrations are multiplicative as required, the actual data “disappear” in the ratio of DATA / CORRECTED_DATA, so there is no danger of faint signals making their way into this model (which would be bad because they’re about to be subtracted from the science data). Put another way, this column will be noise-free. It contains a sum of ratios of analytically-derived quantities: source models (the MODEL_DATA in the work.$i.ms) divided by instrumental (calibration) models (more precisely, multiplied by the reciprocal DATA / CORRECTED_DATA).
  5. Finally, we can use uvsub to subtract this model from the science data. main.ms[CORRECTED_DATA] will now contain the science data with the bright sources peeled. You can then proceed to image, selfcal, etc.

Does it work? It sure does! The results were actually better than I had dared hope.

Demonstration of the workflow with a 10 hr VLA observation. The left panel shows
the image before peeling, the right after. Color scales are the same. The
circles indicate the half-power response of the VLA primary beam at the central
observing frequency, 6 GHz. The CLEAN residual rms at the pointing center
decreases from 3.9 to 2.5 μJy. From Williams et al., 2019.
Demonstration of the workflow with a 10 hr VLA observation. The left panel shows the image before peeling, the right after. Color scales are the same. The circles indicate the half-power response of the VLA primary beam at the central observing frequency, 6 GHz. The CLEAN residual rms at the pointing center decreases from 3.9 to 2.5 μJy. From Williams et al., 2019.

I had probably been wishing for this functionality for, say, five years, before I sat down and implemented it. Rust helped, but really the breakthrough was realizing that I could invert the calibration gains by computing DATA / CORRECTED_DATA. Before that (in retrospect, obvious) idea came to me, I was getting hung up on how to invert a CASA gains table — you can take the reciprocals of all of the numbers in the table, but how does that interact with time-based interpolation? What if you also want to apply a bandpass correction? It just seemed like it was going to be really dodgy. The “empirical” approach isn’t as efficient, but it’s robust, and that’s a tradeoff I’m generally happy to make.

Questions or comments? For better or worse this website isn’t interactive, so send me an email or, uh, Toot me.

To get notified of new posts, try subscribing to my lightweight newsletter or my RSS/Atom feed. No thirsty influencering — you get alerts about what I’m writing; I get warm fuzzies from knowing that someone’s reading!

Later: A Modest Proposal for How to Do Digital Conference “Posters”

Earlier: The xz Backdoor and Release Automation

See a list of all posts.

View the revision history of this page.